CFC SERIES
One of high engineering grade air curtain in industrial application. CFC used to provide a thermal barrier to stop drafts, reduce infiltration of exterior air into heated/air-conditioned industrial areas and prevents the influx of flying insects and dust. They are popular in Warehouse Loading Dock, Train & Bus large Bay door, Truck Drive-in Door.
- Effective Against a 16mph Wind
- Washable Air Filter
- Color: Aluminum Paint (Custom Color or Stainless)
- Custom Made is available upon request
RECOMMENDATIONS
KEY FEATURES
- Optional Heating methods
- Ambient (No Heat)
- Electrical Heated
- Water Heated
- Steam Heated
- Operation Controls
- Door Switch
- Thermostat (Electric Heated Units Only)
- Unit Mounted Switch (Optional)
- Unit Mounted Control Panel: (Lockable Disconnect Switch/AOH Switch) (Optional)
- Network Smart Control (Optional)
- Adjustable Time Delay (0-9999 Second)
- Mounting Methods
- Top Thread Rods Insert Mounting
- Top Brackets Mounting (Optional)
- Both End Extension Bracket Mounting (Optional)
- Nozzle Extension (Optional)
CFC AMBIENT MODEL
Specification
Air curtain shall be Miniveil Model CFC….and shall produce a strong low turbulent air stream with an air velocity at the nozzle of 6500 fpm. The unit is of a rigid welded gauge 14 steel construction (Stainless steel grade 304 or higher available). The unit is designed to be supported at each end without the need for intermediate support. The unit shall consist of double shaft TEFC, 6 pole motor(s), each driven forward curved non overloading fans with each wheel individually supported by two sealed bearings. The fans shall be completely balanced and aerodynamically designed transitions between the fans and the nozzle, and the outlet length of the transitions shall be equal to the full length of the nozzle. The nozzle shall be 4.5” wide and extend the full length of the unit and be moted to the base. It shall be possible to angle the whole nozzle, at least 4” deep in the direction of the air flow, +/- 20 ° to permit directing the air stream in or out through the door.
Operation Controls
The unit shall contain multiple control methods to fully control operation of air curtain:
- Automatic Door Switch Operation
- Air curtain will have the fans activated by door open, and have the fans deactivated by door closed.
- Unit mounted Rocker Switch Control Operation (Optional)
- Air curtain equipped with Rocker switches which can be turn air curtain to High Speed/OFF/Low Speed.
- Wireless Network smart control System (Optional)
- Air curtain can be fully controlled and monitor through your smart phone or computer (No App needs to download).
Control Panel (Optional)
Three phase units require a motor starter control panel which may also include a Lockable Discount Switch, a Hand/Off/Automatic Switch, or Terminal Block for Automatic Door Switch, Air Pressure Sensor (Providing False Signal Alarm), Adjustable Time Delay (allowing the unit to keep running for a period after the door closes). The control panel may be unit mounted at specific location as per request.
Technical Data
MODEL | CFC-1-60 | CFC-1-72 | CFC-1-96 | CFC-1-120 | CFC-1-144 | CFC-2-168 | CFC-2-192 | CFC-2-216 | CFC-2-240 | CFC-2-264 | CFC-2-288 |
Nozzle Length | 60 | 72 | 96 | 120 | 144 | 168 | 192 | 216 | 240 | 264 | 288 |
Max Air Velocity (fpm) | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 |
Max Air Volume (cfm) | 9800 | 11700 | 15700 | 19100 | 23500 | 27500 | 31000 | 34300 | 38200 | 42000 | 45800 |
Motor(s)(hp) | 5 | 5 | 7.5 | 7.5 | 10 | 5+7.5 | 7.5+7.5 | 7.5+7.5 | 7.5+7.5 | 7.5+10 | 10+10 |
Net Weight(Lbs) | 445 | 475 | 615 | 820 | 1020 | 1190 | 1360 | 1585 | 1760 | 1936 | 2200 |
Standard Voltages: 208V/575V, 3 PHASES, 60HZ; Alternate Volt available upon request
SOUND LEVEL: (MEASURED 10’ FROM THE UNIT IN FREE FIELD): CFC-1: 69dbA; CFC-2: 73dbA
CFC ELECTRIC HEATED MODEL
Specification
Air curtain shall be Miniveil Model CFC….and shall produce a strong low turbulent air stream with an air velocity at the nozzle of 6500 fpm. The unit is of a rigid welded gauge 14 steel construction (Stainless steel grade 304 or higher available). The unit is designed to be supported at each end without the need for intermediate support. The unit shall consist of double shaft TEFC, 6 pole motor(s), each driven forward curved non overloading fans with each wheel individually supported by two sealed bearings. The fans shall be completely balanced and aerodynamically designed transitions between the fans and the nozzle, and the outlet length of the transitions shall be equal to the full length of the nozzle. The nozzle shall be 4.5” wide and extend the full length of the unit and be moted to the base. It shall be possible toe angle the whole nozzle, at least 4” deep in the direction of the air flow, +/- 20 ° to permit directing the air stream in or out through the door.
Electric Heating Coil
Air Curtain shall be equipped with a CSA approved Helical Coil Electric Heater with Automatic Reset Thermal Overload, Magnetic Contractor(s), and be mounted and internally prewired on the base for easy installation and servicing. Heater assembly to fit inside the unit. The heater may divide into 2 stages or more as per specific models.
All coils are rated in compliance with the certification program of A.R.I. standard 410-72.
Operation Controls
The unit shall contain multiple control methods to fully control operation of air curtain:
- Automatic Door Switch Operation
- Air curtain will have the fans activated by door open, and have the fans deactivated by door closed.
- Unit mounted Rocker Switch Control Operation (Optional)
- Air curtain equipped with Rocker switches which can be turn air curtain to High Speed/OFF/Low Speed.
- Thermostat Control Operation
- When air curtain has fans activated, the thermostat will have heater on when temperature is below set point and has heater off when temperature is above set point.
- Wireless Network smart control System (Optional)
- Air curtain can be fully controlled and monitor through your smart phone or computer (No App needs to download).
Control Panel (Optional)
Three phase units require a motor starter control panel which may also include a Lockable Discount Switch, a Hand/Off/Automatic Switch, or Terminal Block for Automatic Door Switch, Air Pressure Sensor (Providing False Signal Alarm), Adjustable Time Delay (allowing the unit to keep running for a period after the door closes). The control panel may be unit mounted at specific location as per request.
Technical Data
MODEL | CFC-1-60-E | CFC-1-72-E | CFC-1-96-E | CFC-1-120-E | CFC-1-144-E | CFC-2-168-E | CFC-2-192-E | CFC-2-216-E | CFC-2-240-E | CFC-2-264-E | CFC-2-288-E |
Nozzle Length | 60 | 72 | 96 | 120 | 144 | 168 | 192 | 216 | 240 | 264 | 288 |
Max Air Velocity (fpm) | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 |
Max Air Volume (cfm) | 9800 | 11700 | 15700 | 19100 | 23500 | 27500 | 31000 | 34300 | 38200 | 42000 | 45800 |
Motor(s) (hp) | 5 | 5 | 7.5 | 7.5 | 10 | 5+7.5 | 7.5+7.5 | 7.5+7.5 | 7.5+7.5 | 7.5+10 | 10+10 |
Heating Power (kw) | 98 | 117 | 157 | 191 | 235 | 274 | 313 | 350 | 390 | 430 | 470 |
Temp Rise (F) | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
Net Weight (Lbs) | 540 | 580 | 750 | 980 | 1215 | 1420 | 1620 | 1920 | 2150 | 2340 | 2550 |
Standard Voltages: 208V/575V, 3 PHASES, 60HZ; Alternate Volt available upon request
SOUND LEVEL: (MEASURED 10’ FROM THE UNIT IN FREE FIELD): CFC-1: 69dbA; CFC-2: 73dbA
CFC STEAM HEATED MODEL
Specification
Air curtain shall be Miniveil Model CFC….and shall produce a strong low turbulent air stream with an air velocity at the nozzle of 6500 fpm. The unit is of a rigid welded gauge 14 steel construction (Stainless steel grade 304 or higher available). The unit is designed to be supported at each end without the need for intermediate support. The unit shall consist of double shaft TEFC, 6 pole motor(s), each driven forward curved non overloading fans with each wheel individually supported by two sealed bearings. The fans shall be completely balanced and aerodynamically designed transitions between the fans and the nozzle, and the outlet length of the transitions shall be equal to the full length of the nozzle. The nozzle shall be 4.5” wide and extend the full length of the unit and be moted to the base. It shall be possible toe angle the whole nozzle, at least 4” deep in the direction of the air flow, +/- 20 ° to permit directing the air stream in or out through the door.
Steam Heating Coil
Air Curtain shall be equipped with a single row heating coil on nonferrous copper tubes with 10 aluminum fins per inch, and coil designed to operate at a maximum of 75p.s.i. and 320 F Steam. The supply and return connections shall be 1.5” MPT and shall be to the right(left) side of the unit as per request.
All coils are rated in compliance with the certification program of A.R.I. standard 410-72.
Operation Controls
The unit shall contain multiple control methods to fully control operation of air curtain:
- Automatic Door Switch Operation
- Air curtain will have the fans activated by door open, and have the fans deactivated by door closed.
- Unit mounted Rocker Switch Control Operation (Optional)
- Air curtain equipped with Rocker switches which can be turn air curtain to High Speed/OFF/Low Speed.
- Wireless Network smart control System (Optional)
- Air curtain can be fully controlled and monitor through your smart phone or computer (No App needs to download).
Control Panel (Optional)
Three phase units require a motor starter control panel which may also include a Lockable Discount Switch, a Hand/Off/Automatic Switch, or Terminal Block for Automatic Door Switch, Air Pressure Sensor (Providing False Signal Alarm), Adjustable Time Delay (allowing the unit to keep running for a period after the door closes). The control panel may be unit mounted at specific location as per request.
Technical Data
MODEL | CFC-1-60-S | CFC-1-72-S | CFC-1-96-S | CFC-1-120-S | CFC-1-144-S | CFC-2-168-S | CFC-2-192-S | CFC-2-216-S | CFC-2-240-S | CFC-2-264-S | CFC-2-288-S |
Nozzle Length | 60 | 72 | 96 | 120 | 144 | 168 | 192 | 216 | 240 | 264 | 288 |
Max Air Velocity (fpm) | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 |
Max Air Volume (cfm) | 9800 | 11700 | 15700 | 19100 | 23500 | 27500 | 31000 | 34300 | 38200 | 42000 | 45800 |
Motor(s)(hp) | 5 | 5 | 7.5 | 7.5 | 10 | 5+7.5 | 7.5+7.5 | 7.5+7.5 | 7.5+7.5 | 7.5+10 | 10+10 |
Steam (mbtu/hr) | 365 | 437 | 581 | 710 | 873 | 1018 | 1164 | 1280 | 1420 | 1560 | 1700 |
Temp Rise (F) | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 | 35 |
Net Weight (Lbs) | 445 | 475 | 615 | 820 | 1020 | 1190 | 1360 | 1585 | 1760 | 1936 | 2200 |
Standard Voltages: 208V/575V, 3 PHASES, 60HZ; Alternate Volt available upon request
SOUND LEVEL: (MEASURED 10’ FROM THE UNIT IN FREE FIELD): CFC-1: 69dbA; CFC-2: 73dbA
Rating Based on 70 Degree F entering air, 5 p.s.i. steam.
CFC HOT WATER HEATED MODEL
Specification
Air curtain shall be Miniveil Model CFC….and shall produce a strong low turbulent air stream with an air velocity at the nozzle of 6500 fpm. The unit is of a rigid welded gauge 14 steel construction (Stainless steel grade 304 or higher available). The unit is designed to be supported at each end without the need for intermediate support. The unit shall consist of double shaft TEFC, 6 pole motor(s), each driven forward curved non overloading fans with each wheel individually supported by two sealed bearings. The fans shall be completely balanced and aerodynamically designed transitions between the fans and the nozzle, and the outlet length of the transitions shall be equal to the full length of the nozzle. The nozzle shall be 4.5” wide and extend the full length of the unit and be moted to the base. It shall be possible toe angle the whole nozzle, at least 4” deep in the direction of the air flow, +/- 20 ° to permit directing the air stream in or out through the door.
Hot Water Heating Coil
Air Curtain shall be equipped with a single row heating coil on nonferrous copper tubes with 10 aluminum fins per inch, and coil designed to operate at a maximum of 250p.s.i. and 300 F Hot water. The supply and return connections shall be 1.5” MPT and shall be to the right(left) side of the unit as per request.
All coils are rated in compliance with the certification program of A.R.I. standard 410-72.
Operation Controls
The unit shall contain multiple control methods to fully control operation of air curtain:
- Automatic Door Switch Operation
- Air curtain will have the fans activated by door open, and have the fans deactivated by door closed.
- Unit mounted Rocker Switch Control Operation (Optional)
- Air curtain equipped with Rocker switches which can be turn air curtain to High Speed/OFF/Low Speed.
- Wireless Network smart control System (Optional)
- Air curtain can be fully controlled and monitor through your smart phone or computer (No App needs to download).
Control Panel (Optional)
Three phase units require a motor starter control panel which may also include a Lockable Discount Switch, a Hand/Off/Automatic Switch, or Terminal Block for Automatic Door Switch, Air Pressure Sensor (Providing False Signal Alarm), Adjustable Time Delay (allowing the unit to keep running for a period after the door closes). The control panel may be unit mounted at specific location as per request.
Technical Data
MODEL | CFC-1-60-HW | CFC-1-72-HW | CFC-1-96-HW | CFC-1-120-HW | CFC-1-144-HW | CFC-2-168-HW | CFC-2-192-HW | CFC-2-216-HW | CFC-2-240-HW | CFC-2-264-HW | CFC-2-288-HW |
Nozzle Length | 60 | 72 | 96 | 120 | 144 | 168 | 192 | 216 | 240 | 264 | 288 |
Max Air Velocity (fpm) | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 | 6500 |
Max Air Volume (cfm) | 9800 | 11700 | 15700 | 19100 | 23500 | 27500 | 31000 | 34300 | 38200 | 42000 | 45800 |
Motor(s) (hp) | 5 | 5 | 7.5 | 7.5 | 10 | 5+7.5 | 7.5+7.5 | 7.5+7.5 | 7.5+7.5 | 7.5+10 | 10+10 |
Hot Water (mbtu/hr) | 188 | 225 | 299 | 365 | 499 | 582 | 665 | 670 | 730 | 803 | 880 |
Temp Rise (F) | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 |
Net Weight (Lbs) | 445 | 475 | 615 | 820 | 1020 | 1190 | 1360 | 1585 | 1760 | 1936 | 2200 |
Standard Voltages: 208V/575V, 3 PHASES, 60HZ; Alternate Volt available upon request
SOUND LEVEL: (MEASURED 10’ FROM THE UNIT IN FREE FIELD): CFC-1: 69dbA; CFC-2: 73dbA
Rating Based on 70 Degree F entering air, and 180 degrees hot water.